Blogs
Acoustic Micro-Imaging
Acoustic Micro-Imaging Customer Case The customer is a leader in the field of acoustic micro-imaging. They use pulse ultrasound to image non-human materials. The ultrasound frequency used is between 100 and 200 MHz, as the materials they study can handle these frequencies (one cannot normally use such high frequencies with human tissue). The customer's PRF (Pulse Repeat Frequency) is approximately 4 KHz, with a PRI (Pulse Repeat Interval) of 250 ms. They need to capture approximately 2 ms (1,000 points) of data for each pulse. The customer wants scope emulation software to allow verification of board operation without having [...]
Non-Destructive Testing (NDT) Scanning Inspection
Non-Destructive Testing (NDT) Scanning Inspection Customer Case The customer is testing interior of pipes with time-resolved fluorescence, a Photo Multiplier Tube (PMT), a transducer with 8 MHz BandWidth and an integration chamber. They are searching for rare events and the scan width is approximately 3.5 inches. Multiple Record: 350 scans x 3 Kpts. GaGe Case Solution We recommended 5X-10X over sampling - therefore CompuScope 14100, CompuScope 12100, or even the 8-bit CS8500 may be sufficient. For a CS8500 Single Record example, say, at the single-channel sampling-rate of 50 MS/s, a 3000 point (i.e. 3 KS) acquisition would take about [...]
Non-Destructive Testing (NDT) of Concrete Structures
Non-Destructive Testing (NDT) of Concrete Structures Customer Case Our customer needs to perform Non Destructive Testing (NDT) to test concrete. The testing method involves using a special hammer mounted with a geophone, which serves as a transducer. They strike the concrete structure with the hammer and record the results for analysis. A definitive echo in the signal will be appear should there be a crack or a weak point in the concrete. GaGe Case Solution The customer was looking for a low-cost board that would be able to sample at 20 MHz or more, so we recommended the CompuScope [...]
Non-Destructive Testing (NDT) for Steel Manufacturing
Non-Destructive Testing (NDT) for Steel Manufacturing Customer Case The customer is a custom-built contractor of Non-Destructive Test (NDT) instruments for steel manufacturing. NDT uses ultrasonic pulses to scan through thick sheets of metals for possible causes of early wear, such as cracks or impurities. The stimulus is a stream of ultrasonic pulses. The response is their reflection from various depths. The center frequencies used by this customer are in the range of 250 KHz to 2.25 MHz and pulses are about 10 microseconds. The pulse repeat frequency (PRF) is less than 1 KHz. The thickness of steel sheets is [...]
Galvannealing Phosphor Thermometry
Galvannealing Phosphor Thermometry Customer Case During the process of galvanizing, steel is dipped in a bath of liquid tin to increase its resistance to oxidation and moisture. After galvanizing, a precise heat treatment allows control of the mechanical properties of the final galvanized steel. This heat treatment is known as galvannealing. During galvannealing, precise temperature control is necessary to promote the desired grain growth in the steel's tin-rich coating. Galvanneal thermometry is difficult. The rolling of the hot steel makes contact thermocouples and optical pyrometry impractical. A customer's galvanneal furnace is equipped for phosphor thermometry. This novel technique uses [...]
Machine Tools Characterization
Machine Tools Characterization Customer Case This customer is involved in characterizing machine tools. In order to do this, they need five simultaneous channels capturing 12-bit samples at 50 KSPS, with a 20 us sample width. A total of 5 seconds of data is required. GaGe Case Solution The solution to this problem is a three-card Master/Slave CompuScope 512 system, with each card having 512 Kilosamples of on-board memory. The CompuScope 512 is a 12-bit 5 MSPS A/D card for the ISA bus. As each CompuScope 512 has two channels, this system would provide 6 channels for the customer's application. [...]
Pulsed Electric Field Food Processing
Pulsed Electric Field Food Processing Customer Case Pulsed Electric Field Food Processing is a continuous food processing system in which beverages (with a known conductivity) are pumped through a chamber containing an electrode. Pulses of high voltage electricity are passed across the electrode, thus through the liquid as well. It is a pasteurization technique being studied at Ohio State University. The need is to be able to monitor, display, and record to hard drive storage, voltage and current waveforms. They need to be able to draw information about the pulse duration, peak voltage, etc. from the recorded waveforms. Waveforms [...]
Nuclear Reactor Cooling Liquid Flow Measurements
Nuclear Reactor Cooling Liquid Flow Measurements Customer Case The customer needs to make a flow meter that is able to measure the flow of liquid through a tube. In this case, water is used for nuclear reactor cooling. The obstacle is that the liquid must be measured while the tube remains intact. GaGe Case Solution Since the customer knows the application, he already has his own signal generator that produces the ultrasound, so he only required a good data acquisition card in order to acquire these ultrasonic signals. An amplified version of the signal coming from the transducer goes [...]
Phase Conjugate Sonar
Phase Conjugate Sonar Customer Case Dissipationless physical systems, such as simple planetary motion or a swinging pendulum, exhibit time-reversal invariance. This means that if time were reversed the way a film projector can be, then the resulting motion would be allowed by the equations governing the system. It follows that if all velocities in a dissipationless system are suddenly reversed, the system will follow a time-reversed trajectory. Dissipationless or adiabatic wave propagation is time-reversal invariant. Phase Conjugate Optics involves the deliberate reversal of complex light paths. A customer is doing Phase Conjugate Sonar using sound instead of light. The [...]
Acoustic Engineering with Stimulus Response System
Acoustic Engineering with Stimulus Response System Customer Case The performance of music without electrical amplification requires precise acoustic engineering of its venues. A customer advises concerning large-scale renovations to existing cathedrals, concert halls and opera houses. Renovations may include decoupling the structure from its surroundings to minimize outside noise and redesigning the interior in order to optimize echo patterns. Buildings are acoustically characterized with precision sound equipment. A sound Stimulus, S(t), is generated by a loudspeaker and the Response, R(t) is received by a microphone, where t is time. Usually, the loudspeaker and microphone are positioned at the musician [...]