MADE IN USA BUILT FOR GLOBAL STANDARDS

MADE IN USA
BUILT FOR GLOBAL STANDARDS

Blogs

CAPACITANCE SENSORS FACILITATE 3D IC CONSTRUCTION

[Application Note 70518] To boost device performance, today’s semiconductor and microelectronics manufacturers are building three-dimensional integrated circuits featuring vertically-stacked silicon wafers and dies. The rationale is simple. Exploiting the Z-axis avoids the power and footprint penalties associated with two-dimensional processes. Implementing the rationale, however, is not so simple. Going vertical requires coplanar surfaces to make contact with all pins, pads, and pillars. Problem Typically, manufacturers measure the angle and gap between two planes to determine coplanarity. Bonding tool actuators rely on these angle/gap measurements to adjust components and make sure all device pins and/or solder balls reside on the [...]

By |January 30th, 2023|Comments Off on CAPACITANCE SENSORS FACILITATE 3D IC CONSTRUCTION

CAMERA SHIELD MEASUREMENT

Equipment Setup Equipment Used DTS-25-04 laser head Rotary Stage PC with Digital Microtrak Basic Support software Setup Power is automatic mode. Filter is 100Hz Sample rate is 1000 samples sec The head was operated in diffuse mode (not specular/tilted) Validation of Setup The setup should be validated by performing a total runout scan on the rotary stage with no target present.  The stage should be cleaned with Isopropyl alcohol and allowed to dry prior to the scan. This reduces any dust or dirt accumulation which will give a false reading of runout. A 360-degree runout of the rotary table, [...]

By |January 30th, 2023|Comments Off on CAMERA SHIELD MEASUREMENT

Wireless Measurement of Very Small Gap Changes Inside Rotating Machinery

Solar, Semiconductor Measurement of Ungrounded Targets Thickness, Metrology Description Description This application note describes how to use capacitance for the non-contact, wireless measurement of very small gap changes (distances) between a device and a grounded target. It uses the textile industry as an example, but any industry that uses machinery with continuously rotating drums or motors can benefit from this approach to remote measurement. Capacitance is highly accurate and can support the use of probes that are wireless. In our example, a capacitive sensing system from MTI Instruments eliminated concerns about establishing and maintaining [...]

MTI’s Accumeasure HD Amplifier vs. SmarAct’s PicoScale Interferometer

MTI's Accumeasure HD Amplifier vs. SmarAct's PicoScale Interferometer Research & Development Piezoceramic, 1-3 Pzt / Polymer Composite And Pvdf Film Amplitude Description This application note compares MTI's Accumeasure HD amplifier to SmarAct's Picoscale interferometer in terms of resolution and accuracy for very small displacement measurements. Specifically, this comparison focuses on minimum expected resolution and the effects of noise on accuracy. High resolution interferometers are widely regarded as the instrument of choice for the type of measurements described in this application note, but MTI's technology provides exceptional accuracy and stability. Moreover, [...]

MONITOR ROLLER GAPS AND PARALLELISM

Easy Roller Gap Measurement Ensures Calendering Success Many roll-to-roll finishing processes typically use a calender, or series of hard pressure rollers, to deliver smooth, high-quality products of plastic, textile, or paper (Fig 1). Ensuring a consistent material thickness, however, depends on the ability to monitor, and maintain, a precise gap between rollers. This application note describes a quick and easy means for roller gap measurement. Problem Establishing a roller gap and checking for parallelism across roller width can be a slow and cumbersome procedure. Manual measurement requires multiple sized feeler gauges which can introduce errors. Misinterpreting feeler gauge drag, [...]

By |January 27th, 2023|Comments Off on MONITOR ROLLER GAPS AND PARALLELISM

Testing for Connector Failure Due to Vibration or Shock

Testing for Connector Failure Due to Vibration or Shock Mobile Communications Equipment Needs Reliable Connectors That Will Not Disconnect with Shock or Vibration Introduction A large multinational company approached MTI to provide a sensor capable of measuring displacement that also wouldn’t load the target (connector). Shock and vibration testing would span 2-15G and the target connectors were very small. Application MTI’s 2100 optical displacement sensor system is ideal for this kind of application because very small probes can be used and they measure displacement via reflected light. Of course, reflected light does [...]

Connecting Encoders to MTI’s Digital Accumeasure

Connecting Encoders to MTI's Digital Accumeasure MTI's Digital Accumeasure D has the ability to accept one or two digital quadrature encoders. The encoders can be linear slide-type or rotary. Digital encoders allow for tracking the position of capacitive probes such that you can synchronize a probe's position with the probe's displacement data. Two common examples are: Rotary shaft runout: shaft (radial) displacement vs. angular encoder position X/Y position of probes measuring wafer thickness (map wafer thickness) Accumeasure software (basic and measurement) allows the display of instantaneous encoder counts as well as probe displacement data; however, [...]

Foam Density Measurement: Capacitance Sensors vs. Nuclear Gauges

Foam Density Measurement: Capacitance Sensors vs. Nuclear Gauges Foam Density Measurement Manufacturing EV Battery Production Thickness, Distance This application note from MTI Instruments compares two technologies for measuring foam density: capacitance sensors and nuclear gauges. It examines the basic operating principles of each technology and explains why capacitance measurement is recommended for in-line measurement during foam manufacturing. Capacitance Sensors Capacitive probes are non-contact devices that use electric fields to measure foam density. In combination with a thickness value, a density measurement may be calculated. These probes consist of a capacitance [...]

ADDING A DIGITAL PANEL METER TO MTI ANALOG OUTPUT PRODUCTS

How To Use Digital Displays with Analog OutputsMTI Microtrak 3 Lasers and some of our Accumeasure amplifiers such as the Accumeasure 9000 only have analog outputs. If you wish to add a digital display, then the Lascar Panel pilot © makes a nice cost effective (~ $110) addition – Fig 1. These Digital panel meters have both 1 & 2 channel display capability and the user can customize the display with a variety of interesting formats. The meter can operate off 4-30VDC which is compatible with the MT-3 power supply and the panel meter inputs can handle 0-10V which is compatible with [...]

By |January 27th, 2023|Comments Off on ADDING A DIGITAL PANEL METER TO MTI ANALOG OUTPUT PRODUCTS

Thickness Measurement of Dielectric Materials

Thickness Measurement of Dielectric Materials Manufacturing EV Battery Production Thickness, Distance --- Description --- Introduction Many applications, both in manufacturing and research, require precise material thickness measurements. This becomes especially difficult if the material is moving, is non conductive and/or translucent to clear. The specifics of your application may make accurate measurements difficult; many circumstances prohibit contact measurement, and make laser measurements difficult or impossible, for example with thin clear materials such as glass, sapphire, plastic . In cases such as these, capacitance measurement provides a highly accurate and cost-effective solution. [...]