MADE IN USA BUILT FOR GLOBAL STANDARDS

MADE IN USA
BUILT FOR GLOBAL STANDARDS

Blogs

MTI Instruments’ PBS-4100+ Series Training Eligible for FAA Training Credit

MTI Instruments' PBS-4100+ Series Training Now Eligible for Credit Under William (Bill) O'Brien Aviation Maintenance Technician (AMT) Awards Program ALBANY, N.Y., Feb. 23, 2021 /PRNewswire/ -- MTI Instruments, Inc. (MTI Instruments), a wholly-owned subsidiary of Mechanical Technology, Incorporated (OTCQB:MKTY), today announced that its training course on the PBS-4100+ engine vibration measurement and balancing system is now credit-eligible under the Federal Aviation Administration's (FAA's) William (Bill) O'Brien Aviation Maintenance Technician (AMT) Awards Program. With the new credit designation, MTI Instrument's course, "Vibration Analysis and Engine Balancing Using the PBS-4100 System," can earn an eligible individual up to 16 hours of credit towards AMT Awards issued through the FAA [...]

By |February 24th, 2021|Categories: Brand-MTI, Industry-Aerospace, Industry-Government/Military, News-MTI, News-MTI-PBS, News-Products, Press Releases-Vitrek, Products-MTI-Engine Balancing, Z-REPUB, z1|Comments Off on MTI Instruments’ PBS-4100+ Series Training Eligible for FAA Training Credit

Industrial

Industrial The following example case studies demonstrate how GaGe products and services have been successfully applied in various data acquisition industrial applications. We encourage you to contact us and discuss your application in more detail with our engineering team. GaGe can provide tailored custom hardware and software solutions to meet specific application requirements. Industrial Nuclear Reactor Tube Testing Avionics Bus Monitoring Improving Performance of Gas Compressors Gas Turbine Monitoring Plasma Coating of Airplane Parts Film Sound Quality Control Monitoring Critical Variables Electrical Cable Testing Nuclear Reactor Cooling Liquid Flow Measurements Pulsed Electric Field Food Processing Machine Tools [...]

By |March 13th, 2023|Comments Off on Industrial

MTI’s Accumeasure HD Amplifier vs. Laser Interferometer

Achieving high resolution and accuracy for very small displacement measurements is generally an expensive and complex undertaking.  The typical instrument of choice for achieving the accuracy required (picometer resolution with nanometer accuracy) is a laser interferometer.  However, MTI Instruments Accumeasure D200HD Amplifier provides exceptional accuracy and stability while coming in at significant cost savings with ease of use. We decided to pit the AccumeasureHD vs a Laser Interferometer and compare results.  Specifically, this comparison focuses on minimum expected resolution and the effects of noise on accuracy.  Micro positioning applications include measuring the mask height of semiconductor wafers during lithography. The [...]

By |February 23rd, 2021|Categories: Brand-MTI, Industry-Compliance Testing, Industry-Manufacturing, MTI Blog, News-MTI, News-Products, Products-MTI-Capacitance, Z-REPUB, z1|Comments Off on MTI’s Accumeasure HD Amplifier vs. Laser Interferometer

Radar Altimeter

Radar Altimeter Customer Case In this RADAR application the customer has pulses coming in at 1660 Hz. For every pulse they need to capture 500 samples which, at that rate, will amount to 1.7 Megs of data every second. The experiment will be running for at least a few minutes. They would then like to log all the captured data to the PC host memory. The final requirement is for the system to be on the PCI bus. By having the system on the PCI bus, the customer can stream the data directly to the PC's memory, which is [...]

By |March 13th, 2023|Comments Off on Radar Altimeter

Webinar Recap: Electrical Safety Testing for the Appliance & Consumer Product Industries

Vitrek is proud to hold educational webinars for our customers in various industries with information and products that are relevant to their applications. One such industry that relies on some of the technology that we offer is the appliance and consumer products industry, which requires extensive electrical safety testing in order to bring their products to market. All products that will be sold to consumers need to be tested by a Nationally Recognized Testing Laboratory (NRTL) in order to earn the proper safety certification. […]

By |February 18th, 2021|Categories: Blog, Brand-Vitrek, Industry-Consumer Products, Industry-Manufacturing, News-Vitrek, z1|Comments Off on Webinar Recap: Electrical Safety Testing for the Appliance & Consumer Product Industries

Ultra High-Speed Radar

Ultra High-Speed Radar Customer Case This application requires the acquisition of very fast analog signals at relatively slow sample rates for a long period of time. In other words, the input bandwidth requirement is very high (1 GHz), but the sampling rate needs to be no more than 5 or 6 MSPS. The most important requirement is that the acquisition must go on, without any breaks, for many hours. The customer does not need very high dynamic range. In fact, a 4-bit A/D converter will be sufficient. The customer has already identified a 4-bit A/D chip from TRW which [...]

By |March 13th, 2023|Comments Off on Ultra High-Speed Radar

Wafer Backgrinding and Semiconductor Thickness Measurements

Wafer backgrinding is the first step in semiconductor packaging, the process of encasing one or more discrete semiconductor devices or integrated circuits (IC) for protection. Known also as wafer thinning or wafer lapping, backgrinding reduces wafer thickness to allow stacking and high-density IC packaging. Wafer thickness also determines package height, an important consideration as smartphones, laptops, and other electronic devices become thinner. With MEMS, wafer thinning also controls the proof mass for devices such as accelerometers or the diaphragm thickness for pressure sensors. Etching the surface of the wafer produces the IC but grinding the backside is what produces [...]

Radar Rackmount System for Large Record Lengths

Radar Rackmount System for Large Record Lengths Customer Case The customer needs to acquire data from his radar system at a sampling rate of 1.5 MSPS for two channels (I & Q). At the moment, this data must be acquired for at least 10 seconds, but the record length may increase by almost 100 times in the future. This equipment needs to be installed in a rackmounted environment, so the host computer must have rackmount capability. An integrated monitor is also important as it eliminates the need to purchase a rack-mounted monitor. Keyboard and mouse must also be rackmountable. [...]

By |March 13th, 2023|Comments Off on Radar Rackmount System for Large Record Lengths

The Growing Need for Industry 4.0 Testing and Validation Tools

Industry 4.0 means that manufacturers need to test and validate more sensors. MTI Instruments 1510A portable signal generator can help. Industry 4.0 is spurring a dramatic increase in the number of sensors that manufacturers need to install, test, validate, and maintain. Although these industrial sensors are packaged to withstand harsh environments, they’re still susceptible to performance-related problems. Whether it’s to support predictive maintenance, asset monitoring, or process automation, proper testing and validation is required to keep systems running smoothly. Otherwise, the data that sensors collect won’t enable the operators of smart factories to make the right decisions. Smart [...]

By |January 21st, 2021|Categories: Brand-MTI, Industry-Cable Test, Industry-Compliance Testing, MTI Blog, News-MTI, Products-MTI-Capacitance, Products-MTI-Laser/Fiber Optic, Products-MTI-Signal Generators, Z-REPUB, z1|Comments Off on The Growing Need for Industry 4.0 Testing and Validation Tools

Interfacing to Offset IF Radar Altimeter

Interfacing to Offset IF Radar Altimeter Customer Case The customer is using an offset IF radar to map forest terrain density. The equipment will be mounted in an aircraft, which will also be carrying a Global Positioning System (GPS) for reference. The plane will fly at an altitude of 10,000 feet. A 512 ns radar pulse will be sent out and a return pulse will be received about 20 uS later, from which 10,000 samples will be acquired. After the pulse is received, there will be a relatively long re-arm time of about 250 to 300 uS for the [...]

By |March 13th, 2023|Comments Off on Interfacing to Offset IF Radar Altimeter
Go to Top